SBOM by manufacturer: what Siemens, Beckhoff, Rockwell and ten others actually provide
Frequently asked questions
Everything without its own network identity: EtherCAT terminals at Beckhoff, Omron, Festo and Bosch Rexroth, X20 modules and POWERLINK devices at B&R, rack modules at Rockwell, Schneider and Mitsubishi, terminal bus modules at WAGO, expansion modules of the Pilz and SICK safety controllers, IO-Link sensors behind every master. They only get into the list via the controller or the master, with PROFINET heads as submodules with I&M0 per slot. Which route works for which manufacturer is in the table and in the respective article.
Siemens and SICK with their own provider (both in the BSI aggregator), Schneider Electric with its own provider without a ROLIE feed, B&R via the ABB PSIRT feed, and Beckhoff, WAGO, Phoenix Contact, Pilz and Festo via CERT@VDE. Rockwell announces CSAF, but no provider can be found. Bosch Rexroth, Omron and Mitsubishi publish only HTML or PDF; for Mitsubishi and Rockwell, CISA provides CSAF documents.
Because manufacturers do not identify hardware via CPE: Siemens uses the MLFB, Phoenix Contact the article number, WAGO order numbers with wildcards, Festo and SICK part numbers, Rockwell catalog numbers, Bosch Rexroth material numbers, each with a firmware range. CPE appears only sporadically, at Beckhoff for software packages, at WAGO and Pilz for operating systems. The device list therefore has to carry these numbers and the firmware version.