IO-Link SBOM: what the master provides about every sensor and what it does not
Frequently asked questions
According to specification V1.1.3, VendorID and DeviceID (Direct Parameter Page) as well as VendorName (ISDU 0x10) and ProductName (0x12) are mandatory. ProductID (order number), SerialNumber, HardwareRevision and FirmwareRevision (0x13–0x17) are optional; the large sensor manufacturers fill them as a rule, but it is not guaranteed.
Only through the IO-Link master. It hands out the device data through its fieldbus submodule (with PROFINET via IOL_CALL or engineering tool), through OPC UA according to OPC 30120 or through the REST interface "JSON Integration for IO-Link". First the master itself has to be found in the network, for example via PROFINET DCP or EtherNet/IP ListIdentity.
The VendorID is the same number as the PI vendor ID and can be resolved through the public PI vendor table. The DeviceID is manufacturer-internal and unique only together with the VendorID; the assignment to the product is provided by the IODD, publicly searchable in the IODDfinder of the IO-Link Community with more than 7,500 device descriptions.